Learn moreCarbon monoxide is the one hazard you can't see or smell, so it's measured, never guessed. A combustion analyzer reads CO, O2, and stack temp, a draft gauge confirms the flue, and a worst-case (BPI-style) depressurization test catches the spillage a calm-day check misses — because CO faults often come from the house pulling against itself, not just the appliance. We correct the real source — tune, draft fix, makeup air, or flue resize — then re-measure. The before-and-after numbers are the record that the hazard is actually gone.
Prices shown are starting estimates and may change with the condition, access, and scope we find on site. Only a written quote from an on-site visit is a price we commit to.
A carbon monoxide problem is the one chimney hazard you can't see, smell, or afford to guess about. When a CO detector alarms, when a flame burns wrong, or when a tight home starves an appliance of air, the difference between a real fix and a dangerous reassurance is whether someone measured it. CO and combustion-spillage problems are diagnosed with instruments — combustion analyzers, draft gauges, and worst-case depressurization testing — the source corrected, and the fix verified by re-reading the numbers.
CO comes from incomplete combustion and from flue gases spilling into the house instead of going up the chimney, and the cause is found by measurement, not intuition. The appliance is probed with a combustion analyzer to read CO, O2, and stack temperature, draft measured in inches of water column at the draft hood, and a worst-case depressurization (BPI-style) test run — doors closed and exhaust fans running to put the house at its most negative — to see whether the flue still drafts or spills under real-world conditions. A tight, exhaust-heavy modern home can pull combustion gases back down a chimney that tests fine on a calm day; only worst-case testing catches it.
Once the mechanism is known, it's corrected at the source. A mis-tuned appliance has its burner tuned into spec. A flue spilling on a draft problem gets the draft fixed — resizing, a draft-inducer, or a height correction. A house depressurizing the combustion zone gets combustion air added or return leaks sealed. An oversized common flue orphaning a lone water heater after a furnace upgrade gets re-lined to the correct size. The fix matches the measured finding — not a parts-swap guess.
The non-negotiable final step is re-verification. After the correction, the combustion and draft readings are re-run and re-tested under worst-case conditions to confirm CO is in spec and the flue draws without spilling, with the before-and-after numbers documented. Detection is addressed too: standard UL-2034 alarms only sound at 70 ppm and ignore the chronic 5–30 ppm exposure that causes long-term harm, so where appropriate low-level (7-ppm) monitors are placed near combustion appliances and sleeping areas, and a spillage interlock can be wired to shut an appliance down on backdraft.
At Texas Chimney Experts, a carbon monoxide diagnosis & combustion safety is never guesswork. We scope every job from a graded, photographed inspection first — the NFPA 211 level the evidence calls for — so the work is matched to what your flue and masonry actually need, with the report to prove it. The documented inspection is the record the carbon monoxide diagnosis & combustion safety is built on.
Chimney inspectionA carbon monoxide diagnosis & combustion safety isn't a matter of opinion — it's held to published national standards. Texas Chimney builds every job to the named codes below and documents it, so the work is provably right for an inspector, an insurer, or a future buyer. These are the universal standards; your city's permit and inspection requirements are confirmed with the local authority before we pull the job.
To confirm spillage we put the house into worst-case depressurization per BPI combustion-safety practice — doors closed, every exhaust running — and measure whether the combustion appliance zone still drafts.
Correcting the source is not the finish line: combustion readings, draft readings, and the worst-case test are all re-run to prove CO is in spec and the flue draws without spilling, and the before/after numbers go into the record.
Because a standard UL-2034 alarm stays silent until 70 ppm, low-level (≈7-ppm) monitors go near appliances and sleeping areas to catch the chronic exposure those alarms ignore.
Codes cited are the established national standards (NFPA, UL, IRC) that govern this service. The adopted code edition, permit, and inspection requirements vary by city —Texas Chimney verifies them with your local authority having jurisdiction on every job.
Read CO, O2, and stack temp with the combustion analyzer, and measure draft right at the hood.
Force a worst-case depressurization scenario with doors shut and exhaust running, so any spillage shows itself.
Per what the finding shows: tune the burner, correct the draft, add combustion air, or resize an orphaned flue.
Take the readings and worst-case test again, log before and after, and set low-level monitors or an interlock if you want them.
We've worked on 1,000+ DFW homes over 10+ years. Every job — small sweep or full rebuild — runs the same way: certified technicians, written quotes, photo reports, warranty in writing.
CO, O2, and stack temperature are read straight off the appliance with a combustion analyzer, so the numbers are measured on site rather than estimated
Worst-case (BPI-style) depressurization test catches intermittent spillage
The correction is matched to what the readings show, then the same numbers are pulled again to confirm it held
Low-level (7-ppm) monitors and spillage-interlock wiring can be added on request
Family-owned, CSIA-certified, NFPA 211–compliant. We're the team you call when you want it done right the first time — no rotating subcontractors, no upsell pressure, no surprises. Same techs, same trucks, same standard.

The standard is condition-driven, not calendar-driven: NFPA 211 ties cleaning to a measured 1/8" of creosote accumulation, and a Level 1 inspection is the way we confirm you've reached it. For a wood-burning fireplace in regular use that typically lands at once per heating season — but we measure the buildup and tell you what the flue actually shows rather than assuming.
Yes — and verifiably so. Our inspectors hold current CSIA (Chimney Safety Institute of America) certifications you can confirm yourself in the CSIA member directory at csia.org, and our fireplace work is handled by NFI specialists. We name the standard we inspect to so you can check the credential behind the report.
Yes. We respond 24/7 (subject to crew availability) to the situations that can't wait for a diagnosis later — an active water leak into the home, an animal trapped in the flue, post-fire hazards, and storm damage. We make the system safe first, then document the cause; same-day in most cases.
Always — and with the evidence attached. Before any work starts you receive a written quote backed by photos of exactly what we found and why it needs attention. Final pricing follows the documented condition of the chimney and anything the inspection turns up, not a number guessed before we've looked.
Inspection Program is our annual maintenance plan at $19.99/month ($240/year): a documented Level 1 inspection and sweep every year ($248 value), priority scheduling, 10% off all repairs, and emergency-response priority. It's the way to keep a year-over-year record of your system's condition. Cancel anytime, no contract.